Shree Guru Enterprises India
Shree Guru Enterprises India
Send Email
0804778294388% Response Rate
Search

Home » Products & Services » Transformer Oil Filtration Manufacturers In India


Transformer Oil Filtration Manufacturers In India

Providing you the best range of transformer oil filtration plant and transformer oil filter machine with effective & timely delivery.

Transformer Oil Filtration Plant

REQUEST CALLBACK

Transformer Oil Filtration Plant
  • Transformer Oil Filtration Plant
  • Transformer Oil Filtration Plant
  • Transformer Oil Filtration Plant
  • +4 Transformer Oil Filtration Plant
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2,25,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
Flow Rate1200LPH
Plant Capacity1200LPH
Vacuum Level0.6mbar
Power SourceElectric And Diesel
Heater Capacity12 kW
Automation GradeSemi Automatic
MountingTrolley
PhaseThree Phase
ApplicationEhv Substation, Vacuum Drying, Power Transformer, Distribution Transformer
Country Of OriginMade In India

A Transformer Oil Filtration Plant is a specialized industrial system designed to purify, dehydrate, degas, and filter insulating oil used in electrical transformers and other high-voltage equipment. The primary objective is to restore and maintain the dielectric strength and chemical purity of transformer oil, thereby ensuring reliable operation, extended equipment life, and compliance with international standards.
Purpose & Importance

Transformer oil plays a critical role in:

  • Electrical insulation

  • Heat dissipation

  • Arc suppression

Over time, oil becomes contaminated with moisture, gases, acids, sludge, and solid particles, which significantly reduces its insulating properties and accelerates transformer aging. The oil filtration plant removes these contaminants, ensuring safe, efficient, and long-term transformer performance.

 

Key Technical Features
  • Moisture Reduction: ≤ 5 PPM

  • Gas Content: ≤ 0.1%

  • Particle Filtration: Up to 1 micron

  • Dielectric Strength: ≥ 70 kV (BDV)

  • Vacuum Level: ≤ 1 mbar

  • Continuous Operation Capability

  • PLC Automation with Touch HMI (Optional)

Types of Transformer Oil Filtration Plants
  1. Single-Stage Vacuum Filtration Units

  2. Double-Stage High Vacuum Filtration Plants

  3. Mobile Oil Filtration Units

  4. Online Filtration Systems

  5. High Vacuum Oil Dehydration & Degassing Systems


 


Yes! I am Interested

Transformer Oil Filter Machine

REQUEST CALLBACK

Transformer Oil Filter Machine
  • Transformer Oil Filter Machine
  • Transformer Oil Filter Machine
  • Transformer Oil Filter Machine
  • +3 Transformer Oil Filter Machine
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1,45,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
Flow Rate3000 LPH
Filter Rating1 Micron
Heater Capacity36 kW
Power SourceElectric Motor
Automation GradeSemi Automatic
MountingTrolley
PhaseThree Phase
ApplicationPower Transformer
Country Of OriginMade In India

We manufacture Three Phase High Vacuum Transformer Oil Filter Machine & dehydration plants ranging from 300 LPH to 3000 LPH. Each model having 2 types mainly, single stage degassing & 2 stage degassing. Working vacuum of single stage degassing plants is less than 1 Torr. While working vacuum 2-stage plants is less than 0.2 Torr. Our machines are work on Low temperature high vacuum principle. So, running cost of our machine is very minimal.  We also manufacture tailor made plants for our customers such as transformer oil regeneration plants. Recently we have introduced the new series (HV) in addition to single stage (1V) & two stage (2V) of transformer oil filtration & dehydration plants.

The Transformer Oil Filter Machine Capacity Range : 300 LPH to 3000 LPH,General Model Name : SGEI300 Series

The Transformer Oil Filter Plant is engineered with a Low-Temperature & High-Vacuum System to efficiently purify and restore the quality of transformer oil. The primary objectives of this system are:

  • Removal of sediments/sludge,
  • Reduction of moisture content and dissolved gases,
  • Neutralization of acidity,
    ensuring the oil's dielectric and insulating properties meet the required operational standards.

Design Highlights

  1. Operator-Friendly Construction

    • All operational controls, vision ports, and valves are ergonomically placed on one side for easy accessibility.
  2. Key Components

    • Heater Chamber: Maintains oil temperature between 65°C and 90°C.
    • Micron Filter: Removes larger particles and sludge (down to 1 micron).
    • Micron Filter: Captures finer particles (up to 0.5 microns).
    • Degassing Chamber: Eliminates dissolved gases and moisture under high vacuum.
    • Vacuum Pumps: Rotary high-vacuum pumps ensure efficient degassing and moisture removal.
    • Suction & Outlet Pumps: Facilitate the flow of oil into and out of the system.
  3. Leak-Proof Assembly

    • All joints are sealed with nitrile O-rings in precision-machined flanges.
    • The system undergoes a rigorous pneumatic pressure test at 3 kg/cm² to ensure no leakage and to verify desired vacuum leak rates.

Operational Workflow

  1. Oil Suction

    • Transformer oil is drawn into the system from the source via the suction pump.
  2. Heating

    • The oil passes through the heater chamber, where it is gently heated (65°C–90°C).
    • Heating under vacuum prevents oil degradation and ensures the removal of moisture.
  3. Filtration

    • Micron Filter removes sludge and particles larger than 1 micron.
    • Micron Filter captures finer contaminants up to 0.5 microns.
  4. Degassing

    • Heated and filtered oil enters the degassing chamber, where it is showered for maximum surface exposure.
    • Vacuum conditions vaporize and remove dissolved water and gases.
    • Vaporized impurities are extracted by the rotary vacuum pump.
  5. Recirculation and Output

    • Purified oil is recirculated or returned to the source via the outlet pump.

Testing & Quality Assurance

  • The system is pressure-tested at 3 kg/cm² for pneumatic leaks.
  • High vacuum leak rates are verified to ensure system integrity.
  • Filtration performance is tested for achieving specified particle

Additional Information:

  • Item Code: 3000LSGEI
  • Production Capacity: 3LSGEI
  • Delivery Time: 45DAYS
  • Packaging Details: 1BOX
  • Yes! I am Interested

    Transformer Oil Filtration Plant

    REQUEST CALLBACK

    Transformer Oil Filtration Plant
    • Transformer Oil Filtration Plant
    • Transformer Oil Filtration Plant
    • Transformer Oil Filtration Plant
    • +2 Transformer Oil Filtration Plant
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 65,000 / PieceGet Latest Price

    Product Brochure
    Product Details:
    Minimum Order Quantity1 Piece
    Flow Rate4000 LPH
    Capacity2500 LPH
    Plant Capacity2.5KL
    Filter Rating1 Micron
    Vacuum Level0.1 mbar
    Heater Capacity36 kW
    Power SourceElectric Motor
    Automation GradeSemi Automatic
    Break Down Voltage After filtration100
    Water Content0.01
    Max Capacity300-10000LPH
    MountingTrolley
    PhaseThree Phase
    ApplicationVacuum Drying, Power Transformer
    Country of OriginMade in India
    MaterialOil

    We manufacture Three Phase High Vacuum Transformer Oil Filter Machine & dehydration plants ranging from 300 LPH to 3000 LPH. Each model having 2 types mainly, single stage degassing & 2 stage degassing. Working vacuum of single stage degassing plants is less than 1 Torr. While working vacuum 2-stage plants is less than 0.2 Torr. Our machines are work on Low temperature high vacuum principle. So, running cost of our machine is very minimal.  We also manufacture tailor made plants for our customers such as transformer oil regeneration plants. Recently we have introduced the new series (HV) in addition to single stage (1V) & two stage (2V) of transformer oil filtration & dehydration plants.

    The Transformer Oil Filter Machine Capacity Range : 300 LPH to 3000 LPH,General Model Name : SGEI300 Series

    The Transformer Oil Filter Plant is engineered with a Low-Temperature & High-Vacuum System to efficiently purify and restore the quality of transformer oil. The primary objectives of this system are:

    • Removal of sediments/sludge,
    • Reduction of moisture content and dissolved gases,
    • Neutralization of acidity,
      ensuring the oil's dielectric and insulating properties meet the required operational standards.

    Design Highlights

    1. Operator-Friendly Construction

      • All operational controls, vision ports, and valves are ergonomically placed on one side for easy accessibility.
    2. Key Components

      • Heater Chamber: Maintains oil temperature between 65°C and 90°C.
      • Micron Filter: Removes larger particles and sludge (down to 1 micron).
      • Micron Filter: Captures finer particles (up to 0.5 microns).
      • Degassing Chamber: Eliminates dissolved gases and moisture under high vacuum.
      • Vacuum Pumps: Rotary high-vacuum pumps ensure efficient degassing and moisture removal.
      • Suction & Outlet Pumps: Facilitate the flow of oil into and out of the system.
    3. Leak-Proof Assembly

      • All joints are sealed with nitrile O-rings in precision-machined flanges.
      • The system undergoes a rigorous pneumatic pressure test at 3 kg/cm² to ensure no leakage and to verify desired vacuum leak rates.

    Operational Workflow

    1. Oil Suction

      • Transformer oil is drawn into the system from the source via the suction pump.
    2. Heating

      • The oil passes through the heater chamber, where it is gently heated (65°C–90°C).
      • Heating under vacuum prevents oil degradation and ensures the removal of moisture.
    3. Filtration

      • Micron Filter removes sludge and particles larger than 1 micron.
      • Micron Filter captures finer contaminants up to 0.5 microns.
    4. Degassing

      • Heated and filtered oil enters the degassing chamber, where it is showered for maximum surface exposure.
      • Vacuum conditions vaporize and remove dissolved water and gases.
      • Vaporized impurities are extracted by the rotary vacuum pump.
    5. Recirculation and Output

      • Purified oil is recirculated or returned to the source via the outlet pump.

    Testing & Quality Assurance

    • The system is pressure-tested at 3 kg/cm² for pneumatic leaks.
    • High vacuum leak rates are verified to ensure system integrity.
    • Filtration performance is tested for achieving specified particle

    Additional Information:

  • Item Code: TOFM200
  • Production Capacity: 300-2500
  • Delivery Time: 45 DAY
  • Packaging Details: 1 BOX
  • Yes! I am Interested

    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    SB YADAV (Managing Director)
    Shree Guru Enterprises India
    SR No 89 Plot No 1, Bhatsangvi Bhalki, Bidar
    Bidar - 585411, Karnataka, India
    Call Us: 
    Call Response Rate: 88%
    Share Us :



    © Shree Guru Enterprises India. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited